Miscellaneous Tab

Default Unlock Time (minutes)

This is the time duration of an unlock as a fail-safe value in situations where the event duration was not found for the event.  The door would unlock for this amount of time if the duration of the event was 0 or an error occurred during the calculation.

This value can be changed for each door.

Maximum Unlock Duration (minutes)

This is a global value for all doors where a maximum duration for an unlock is enforced.  If the calculated event duration is greater than the maximum unlock duration, the duration will be fixed at the maximum and a warning email will be sent out.

Default Priority (0-200)

This is the default priority setting for sending lock and unlock commands.  200 is the highest priority. This value can be changed for each door.

Note:  Not all door lock types recognize priorities.  (e.g. P2000 locks)

Target C-Cure Version

For version 2.8 and above, you must select the target C-Cure version to login to the api.

Disable Partner Login (v2.7 only)

If your C-Cure version is below 2.8, you can check this to disable the partner integration login requirements that started at v2.8+.

Important:  For v2.8+, you must have to purchase an integration license for C-Cure for the “Streamside Solutions - Events2HVAC” integration.  An installation setup script provided by Streamside Solutions also needs to be run on your C-Cure server.